Drainage calculator

Stone, fabric and pipe for drainage trenches and drains behind walls, the bedding round a pipe, the size of a soakaway and the soil test that decides it.

Drainage calculator

How it is worked out

A trench: stone = width × depth less the pipe, per meter; fabric wraps it with an overlap. Clean stone laid loose weighs about 1.5 t/m³ (see 6.3 and 6.4). A pipe trench is the pipe diameter plus 400 mm wide, with a bed under and cover over the pipe (see 2.1).

A soakaway for a small roof stores the rain from about 16.7 mm of rain (area × 50 ÷ 3,000), divided by the share of voids: 40 % for washed stone, 30 % for rubble, 95 % for crates (see 6.5).

Infiltration rate = water between 75 % and 25 % of the depth ÷ (wetted area at half depth × the time). Do the test three times and use the slowest.

Sources

  1. FHWA-HRT-15-034, open-graded aggregates: No. 57 stone, loosest 95.4 lb/ft³ (1.53 t/m³), densest 108.7 lb/ft³ (1.74 t/m³)
  2. Washington State University Extension: improving drainage: “the trench should be sloped between 0.5% and 1%”
  3. Michigan DOT construction manual: underdrains: “The geotextile blanket should overlap the top of the trench a minimum of 1 foot”
  4. NCDOT Standard Specification 454: segmental gravity walls: “No. 57 stone for a horizontal distance of at least 12 inches”; geotextile between stone and soil, laps 18 in; 100 mm perforated pipe; 8–10 in lifts with hand equipment
  5. US Bureau of Reclamation, Pipe bedding and backfill (training manual 7): 100 mm bedding for pipes up to 250 mm, embedment stone up to 19 mm with 5 % or less fines, both sides raised together within 150 mm, compacted layers of at least 150 mm with tampers, 750 mm cover before heavy machines cross
  6. City of Hendersonville, sewer trench detail: bedding material to 150 mm above the top of the pipe; at least 150 mm of washed stone in rock or wet soil; sand around pressure pipes in 150 mm layers
  7. West Devon Borough Council: infiltration testing (BRE Digest 365 method): pit “0.3 to 1 m wide and 1 to 3 m long”, “Repeat the test 3 times”, rate from the fall between 75 % and 25 %
  8. CNC Building Control (council partnership): soakaway size for an extension: volume = area × 50 ÷ 3,000, voids about 30 %, pieces “no larger than 150mm”, “at least 5m from any building or road”
  9. Runnymede Borough Council: surface water drainage guidance: “n = 0.3 is usually assumed for granular filled infiltration systems”, crates 0.9–0.95, safety factor 2 for homes, 1-in-10-year storm, half empty within 24 h, water table 1 m below
  10. Philadelphia Water: drainage wells checklist: porosity 0.40 for stone storage; traps before the well; 10 ft from buildings
  11. Hastings Borough Council: soakaway advice note: “at least 5m away from any building”; water table at least 1 m below the base; specialist advice on clay and chalk